Refrigeration and Air Conditioning
Hampden's Heating, Refrigeration,
and Air Conditioning training programs, which include basic principles through advanced
industrial systems, utilize actual commercial components throughout. These training
programs follow curriculum guidelines developed by the Air
Conditioning and Refrigeration Institute (ARI) and the Association of Home
Appliance Manufacturers (AHAM). For this reason Hampden equipment is widely used in
secondary and post-secondary vocational schools, community colleges, and technical
institutes.
Furthermore, Hampden's Training Equipment is
manufactured to operate at the specific voltage and frequency of the country in which it
is to be used. Consequently, heating and refrigeration technicians all over the world are
being trained with the help of Hampden Educational Systems.
Hampden offers the widest selection of basic,
intermediate, and advanced programs. This provides the consistency so vital to vocational
and skills training. For advanced automation training, Hampdens Heating,
Refrigeration, and Air Conditioning trainers may be equipped with the sensors and signal
conditioners required for automatic data acquisition, logging, processing, and control.
Additionally, the trainers may incorporate electrical indicators and instructor-programmed
faults.
Hampden trainers contain
EPA-approved, non-CFC, environmentally safe refrigerant.
En Español
Return to top
| MODEL # H-RST-2 BASIC REFRIGERATION CYCLE TRAINER |
 |
The
Hampden Basic Refrigeration Cycle Trainer features "see thru" evaporator and
condenser, permitting students to observe the refrigerant changing from liquid to gas and
back to liquid. This trainer is charged with R-123, a non-CFC approved refrigerant. Four
types of liquid control devices produce five different operating modes, including heat
pump. Students measure pressures with the high-side and low-side gauges, and temperatures
with thermometers placed in strategically located thermometer wells. This mobile trainer
is furnished completely tubed, wired, charged and tested, ready for use.
|

|
| MODEL # H-RST-3B-MP BASIC REFRIGERATION TRAINER WITH OPTIONAL METER
PACKAGE |
H-RST-2
Spec Sheet
|
The
Hampden Basic Refrigeration trainer contains a reversing valve so that the system may be
run as a heat pump in addition to operation as a refrigeration system. Three types of
liquid control devices are included: capillary tube, thermostatic expansion valve, and
hand expansion valve. Sight glasses at the inlet and outlet of the evaporator and
condenser allow students to monitor the change in refrigerant state. Besides the Meter
package, the trainer may be equipped with an Electrical Fault Package, H-RST-FP10E;
a Mechanical Fault Package,
H-RST-FP-M; a Digital Temperature Module with thermocouples, H-RST-TC; and a
Computer Data Logging Package, H-RST-3B-CDL.
|

H-RST-3B-MP
Spec Sheet
|
| MODEL # H-CRT-1 COMMERCIAL REFRIGERATION TRAINER |
 |
The Hampden Commercial Refrigerator Trainer, which contains two evaporators,
simulates a large commercial system. Each evaporator has its own thermostatic expansion
valve, flow meter, and thermostat-controlled solenoid valve. In addition, the system may
operated with expansion valve control or cap tube control. Besides high and low cut-out
switches, the trainer also contains a liquid receiver, a suction accumulator, a heat
exchanger, and an oil separator.
The Hampden Commercial Refrigerator
Trainer contains two evaporators, which may be operated singly or in parallel. Three types
or liquid control devices are included: capillary tube, thermostatic expansion valve, and
an automatic expansion valve.
The Commercial Refrigerator Trainer
may also be equipped with the following options:
- H-CRT-MP Meter Package (voltmeter, ammeter,
wattmeter), allowing the student to monitor electrical characteristics during operation.
- Model H-CRT-10E Electrical Fault Package
|
- Model H-CRT-M Mechanical Fault Package
- Model H-CRT-MT Accessory Package
- Model H-CRT-1-CDL Computer Data Logging Package
|
|

H-CRT-1 Spec Sheet
|
| MODEL # H-IRT-1 INDUSTRIAL REFRIGERATION TRAINER |
 |
The Hampden Industrial Refrigeration Trainer is typical of the Hampden Trainers
that provide students with experience operating and servicing large industrial systems
requiring water-cooled condensers (tube-in-tube and shell-in-tube), electric or hot-gas
defrost systems, cooling towers, hot bypass capacity control systems, crankcase pressure
regulators, crankcase heaters, and pressure pumps. The two evaporators, each with its own
thermostatic expansion valve and pressure gauges, are enclosed with clear plastic panels,
permitting temperatures within this area to fall to realistic levels. Students are able to
configure a number of different systems by opening and closing the appropriate hand
valves. An optional Cooling Tower, MODEL H-ACTK-CT is available to provide cooling
for the condenser.
|

|
| MODEL # H-RST-6 BASIC REFRIGERATION TRAINER |
 |
The Hampden Basic Refrigeration Trainer contains evaporator and condenser coils
made of clear tempered glass, three liquid metering devices, electric reversing valve,
hermetic compressor with liquid receiver and suction accumulator, fan speed controller,
pilot lights, gauges, filter/drier, sight glass and moisture indicator, flowmeter, high
and low pressure controls, digital temperature indicator with thermocouple transfer
switch, solenoid, hand valves, and mobile storage cabinet. Included are
instructor-insertable faults (10 electrical; two mechanical).
|

|
| MODEL # H-RST-8 HEAT PUMP TRAINER |
 |
The Hampden Heat Pump Trainer contains an environmental enclosure with damper,
fan-cooled evaporator, emergency heat, thermal cut-out switch, manual thermostat, digital
thermostat, defrost timer, reversing valve, hermetic compressor with condenser, liquid
receiver, gauges, valves, check valves, high and low pressure switch, filter/dried, sight
glass with moisture indicator, thermostatic expansion valve and cap tube for each
heating/cooling coil, and mobile storage cabinet.
|

|
| MODEL # H-CRT-2 COMMERCIAL REFRIGERATION TRAINER |
 |
The Hampden Commercial Refrigeration Trainer two evaporators, each of which may
be operated separately; three types of liquid control devices: Cap tube, TEV, and AEV;
sight glasses at the inlet and outlet of the evaporator and condenser; pressure gauges;
thermocouples; temperature and pressure controls; heat exchanger; flowmeters; receiver;
oil separator; accumulator, and mobile storage bench. Includes 20 instructor-insertable
faults (18 electrical; 2 mechanical).
|

|
| MODEL # H-RST-9 REVERSE-CYCLE REFRIGERATION TRAINER |
 |
The Hampden Reverse-Cycle Refrigeration Trainer demonstrates the operation of
both an air conditioner and a heat pump. The system utilizes a 1/3 HP hermetic compressor,
two condensers, two evaporators, four metering devices (automatic expansion valve, two
thermostatic expansion valves, capillary tube), control panel and operating instructions.
|

|
| MODEL # H-RST-5 REFRIGERATION AND AIR CONDITIONING TRAINER |
 |
The Hampden Refrigeration and Air Conditioning Trainer is a thermostatic
expansion valve (TXV) controlled refrigerating system. Gauges read evaporation and
condensing pressures, while strategically located temperature wells permit temperature
measurements. The lower portion of the workbench houses the evaporator with its fan,
permitting the compressor to cycle based on evaporating pressure. The trainer includes
faulted components which the instructor can install in place of the good ones.
|

|
| MODEL # H-ACD-1 AIR CONDITIONING DEMONSTRATOR |
 |
The Hampden Air Conditioning Demonstrator provides a pitot tube pressure sensor
and U-tube manometer for measuring air flow, a refrigerant flow meter, wet and dry bulb
thermometers, and gauges for measuring evaporation and condensing pressures. The variable
speed blower, the moisture injector, the duct heating elements, and the eight
interchangeable end plates with size orifices all combine to provide an enormous variety
of operating conditions for students to investigate.
|

|
| MODEL # H-ACTK AIR CONDITIONING AND REFRIGERATION TRAINING KITS |
Click images
for more detail |
Hampden
Air Conditioning and Refrigeration Training Kits are designed to provide the student with
practical experience in connecting, charging, and servicing various types of systems. Each
kit contains the necessary tubing, fittings, and electrical hardware as well as the
compressor, condenser, evaporator, and auxiliary apparatus. Each kit is supplied with a
mobile cart of code-gauge furniture stock steel finished in instrument tan enamel with
4-inch swivel rubber-tired casters.
H-ACTK-1 Beverage Cooler
H-ACTK-2 Single Evaporator Refrigeration/Freezer
H-ACTK-3 Two-door Refrigerator
H-ACTK-4 Grocery Reach-in Cooler
H-ACTK-5 Small Walk-in Meat Cooler
H-ACTK-6 Multiple Case Cooler |
H-ACTK-7 Ice Cream Freezer
H-ACTK-8 Restaurant High-Temperature Salad-Box
H-ACTK-9 Commercial Florist Cooler
H-ACTK-10 Room Air Conditioner
H-ACTK-11 Small Air Conditioner
H-ACTK-HP Heat Pump Trainer |
|
H-ACTK
Spec Sheet
|
| MODEL # H-MACK-9 COMMERCIAL WALK-IN COOLER TRAINER |
 |
The
Hampden Commercial Walk in Cooler Simulator Trainer with optional storage cabinet includes
a 1/2HP hermetic compressor, water-cooled condenser, fan-cooled evaporator, thermostatic
expansion valve, filter/drier, high/low pressure control, pressure control water valve,
liquid receiver, evaporator fan speed control, hardware kit, and cold box.
|
|
| MODEL # H-MACK-10 DOMESTIC AIR CONDITIONING TRAINER |
 |
The Hampden Domestic Air Conditioning Simulator Trainer with optional storage
cabinet includes 1/2 HP hermetic compressor, fan-cooled condenser, fan-cooled evaporator,
thermostatic expansion valve, filter/drier, liquid receiver, low pressure control, room
thermostat, air filter, evaporator fan speed control, hardware kit, and cold box.
|

|
| MODEL # H-ACCS AIR CONDITIONING CONTROLS TRAINER |
 |
The Hampden Air Conditioning Controls Trainer contains all of the actual
components used in the control of commercial and residential heating/cooling systems. The
trainer simulates a system that provides warm air in the winter from an electrical
furnace, and cool air in the summer from an air conditioner. Only the compressor, fans,
and heater are simulated; all other components are ones in actual use. The components are
prewired into a complete thermostat-actuated system, arranged and diagrammed to facilitate
the learning process. Students learn to identify control components by appearance and
function. The instructor is able to insert up to 74 faults, providing the student
experience in systematic troubleshooting techniques. This mobile trainer is supplied
completely wired and tested, ready for use.
|

|
| MODEL # H-CFS-1A COMPRESSOR FAULT SIMULATOR |
 |
The
Hampden Compressor Fault Simulator is designed to give students experience with
troubleshooting hermetic compressors. Up to 16 faults may be inserted into the compressor,
the current relay, the capacitors, the overload relay, or the power wiring. Using a
standard hermetic compressor tester, the student determines the fault and simulates
corrective action via toggle switches on the front of the panel. Lights are used to signal
successful or unsuccessful results of the action. Furnished with cords.
|

|
| MODEL # H-ACD-2 RECIRCULATING AIR CONDITIONING DEMONSTRATOR |
 |
| The
Hampden Recirculating Air Conditioning Demonstrator has been designed to demonstrate the
principles of air conditioning. The student will be able to investigate the theoretical
performance of the R-134a refrigeration system along with the various treatments utilized
in the air flow distribution cycle including heating, cooling, humidification,
de-humidification, recirculation, and mixing. The Recirculating Air Conditioning Demonstrator consists of eight basic segments:
1. Blower
2. Manometers
3. Damper
4. Mixers |
5. Preheater
6. Humidifier
7. Evaporator
8. Reheater |
All controls are centrally located with analog or
digital displays for monitoring. Model H-ACD-2CDL shown.
|

|
| MODEL # H-CPT-1 SINGLE-PHASE COMPRESSOR TRAINER |
 |
The
Hampden Single-Phase Compressor Trainer provides students with the opportunity of
connecting a single-phase compressor in various wiring configurations and varying suction
and discharge pressures to produce realistic operating conditions.
|

|
| MODEL # H-CRT-3 ADVANCED COMMERCIAL REFRIGERATION TRAINER |
 |
| The
Hampden MODEL H-CRT-3 Advanced Commercial Refrigeration Trainer provides a hands-on
introduction to the principal components of a small-scale cold room. This advanced system
incorporates 10 switchable instructor controlled programmed faults inside a lockable
compartment. The trainer consists of a
Control Panel with compressor switch, variable heater control, and variable fan control
(evaporator), cold box (insulated) with heater, compressor (semi-hermetic 1/2HP)
fan-cooled condenser, evaporator with defrost, TEV (1 internal, 2 external). Refrigerant:
R-134a
|

|
| MODEL # H-GHT-1 GAS HEAT TRAINER |
 |
The
Hampden MODEL H-GHT-1 Gas Heat Trainer provides practical experience in the operation,
testing, and troubleshooting gas-fired furnaces, and furnace control system. The Hampden
Gas Trainer is a standard commercial furnace that operates on natural gas. If desired,
however, it may be supplied for propane gas operation. With the H-GHT-1 Gas Heat Trainer,
students will gain an understanding in the following aspects of gas furnace
operations.
1. Learn to identify, by appearance and function, the mechanical and electrical components
of a gas-fired furnace.
2. Develop an appreciation for the safety precautions necessary when connecting,
operating, and servicing furnaces.
3. Observe the correct operating sequence, analyze the reasons for each step, and learn
how the control and protective devices operate.
4. On the rear panel, there are twenty toggle switches which can be used to insert faults
in the electrical circuit. After the instructor has programmed in the desired faults, it
is up to the student to discover the source of the problem.
|

|
| MODEL # H-ACCS-2 AIR CONDITIONER/HEAT PUMP
CONTROLS TRAINER |
 |
The
Hampden MODEL H-ACCS-2 Air Conditioner/Heat Pump Controls Trainer provides students the
opportunity to operate, test, and troubleshoot the electrical controls of a motel-type air
conditioning unit that includes a heat pump. The MODEL H-ACCS-2 contains the actual
control components and devices of a motel type air conditioning unit. The compressor and
fan motors, as well as the heater, are simulated with suitable sized resistances. The
trainer is furnished completely wired and tested. The 20 fault switches located behind a
lockable panel permit the instructor to introduce a variety of malfunctions for student
troubleshooting experience. Power is never applied externally to any of the binding post
test points. When the trainer is energized, realistic voltages appear across the actual
and simulated devices. When de-energized, all components and devices may easily be
isolated for resistance and continuity tests. Power required: Single-phase AC.
|

|
| MODEL
# H-GHT-2 - Gas Heat Trainer |

|
| The
Hampden MODEL H-GHT-2 Gas Heat Trainer contains the actual control components of a
commercial gas heat installation. No gas is required. Although operation of the blower
motor, along with the pilot and main burner are simulated, the spark igniter is real and
fully functional. Up to 15 faults may be inserted from panel on rear. |

|
| MODEL
# H-GHT-3 - Mobile Gas Burner Demonstrator |

|
The
Hampden MODEL H-GHT-3 Mobile Gas Burner Demonstrator provides hands-on experience for
students to conduct tests and adjustments on modern forced air gas furnaces.
The unit consists of:
· Mobile bench
· Gas burner
· Gas manifold
· Forced air heat exchanger
· Draft diverter
· Direct spark ignition
· Thermostat
· Gas solenoid valve
· Instruction Manual and Text Book
The heat exchanger is protected with an expanded metal protector.
Natural gas supply and connection to the gas solenoid are not included, customer is
responsible for meeting all local and state code requirements prior to hook-up.
Liquid Propane model available on request. |

|
| MODEL
# H-GHT-4 - Gas Fired Warm Air Heating Trainer |

|
Hampden's
MODEL H-GHT-4 Gas Fired Warm Air Heating Trainer provides hands-on training by allowing
students to conduct tests and adjustments on a modern forced air gas modulating furnace.
The H-GHT-4 Gas Fired Warm Air Heating Trainer is equipped with two-stage heating and
modulating fan control. This Trainer is fired by either natural gas or liquefied
petroleum.
1. Sealed Combustion: Designed to bring air from outside to support combustion helping to
prevent drafts so that furnace will perform safely.
2. Pressure Switch: if airflow inside heat exchanger is interrupted, the pressure switch
signals the furnace to shut down
3. Stainless Steel Secondary Heat Exchanger: Provides added efficiency by extracting
residual heat from the air after it passes through the primary heat exchanger.
4. Induced Draft Motor Blower: Creates the flow for the gases through the heat exchanger.
For added safety it runs before and after each heating cycle
5. New Igniter Technology with 30 second temperature ramp-up to increase igniter life by
25%
6. Multi-Speed Blower designed for wide range of cooling capacities |
|
| MODEL
# H-OBD-1 - Oil Burner Demonstrator |

|
The
Hampden MODEL H-OBD-1 contains all of the mechanical and electrical components necessary
to operate an actual oil burner of the type used in oil-fired furnaces and hot water
heaters.
With the Hampden Oil Burner Demonstrator the student learns how to adjust, check-out,
operate, and troubleshoot oil burners and their control systems. They learn to identify
components by appearance and function. They acquire the skills required to make mechanical
and electrical connections. Further, the student learns how to identify the symptoms
produced by malfunctioning components; to diagnose, isolate, and repair the system, both
mechanically and electrically.
The following components are included in the Hampden Oil Burner Demonstrator:
Gun Assembly; including oil nozzle, oil pipe, and high-tension wire leads.
Motor; which drives oil burner pump and burner blower to provide air for combustion.
Thermal Overload; protective relay with reset button.
Primary Control; consisting of protective relay to shut down the burner if it fails to
ignite. Wired to provide either "constant ignition", or "intermittent
ignition".
Flame Detector; consisting of a cadmium-sulfide cell that detects the presence of burner
flame. |

|
| MODEL
# H-OBD-2 - Mobile Oil Burner Demonstrator |

|
The
Hampden MODEL H-OBD-2 Mobile Oil Burner Demonstrator duplicates typical field
installations from oil tank to combustion chamber, flame and draft adjustment to indicate
variable firing efficiency and observation of flame and nozzle patterns.
The unit consists of:
· Mobile bench
· Oil burner
· Blast tube pressure gauge
Instant glow combustion chamber w/shield
· Oil fuel filter
· Oil tank w/fuel gauge
· Thermostat
· Protectorelay oil burner control
· Interchangeable nozzles (2)
· Instruction Manual & Text Book
The unit is completely piped including necessary safety valves which would be found in
standard residential systems. |

|
| MODEL
# H-OBD-5 - Domestic Oil Furnace Demonstrator |

|
The
Hampden MODEL H-OBD-5 Domestic Oil Furnace Demonstrator consists of a standard domestic
oil fired furnace modified for educational purposes.
This unit is designed to interface with separately sold Add-On units:
MODEL H-OBD-5P Plenum cabinet
MODEL H-OBD-5PH Power Humidifier
MODEL H-OBD-5C Cooling unit
Faults:
1. Ignition failure
2. Flame failure
3. Electrical power failure
4. High limit conditions
This unit is provided with thermometer access ports for testing stack and limit controls. |

|
| MODEL
# H-OBF-2 - Oil Burner Control Trainer |

|
To
provide students with experience in connecting and operating two standard residential
oil-fired furnace control systems for both winter heating and summer cooling.
The MODEL H-OBF-2 contains all of the standard control components used with isolated
heating/cooling systems of oil-fired furnaces of both the stack relay type and the cadmium
sulfide flame sensing relay type. Pilot lamps indicate the operation of the simulated air
conditioning contactor, the oil burner, and the blower motor. Input power is single-phase
AC through a power cord and fused disconnect switch. All AC supply circuits are prewired.
Students connect the low voltage circuits via patch cords (supplied) between Hampden HR-1S