COMPUTER AIDED DESKTOP TRAINERS
COMPUTER SIMULATED
OPERATION & TROUBLESHOOTING
Schematic and Pictorial Test Points
Specification Chart
Improper Equipment Use Warning
Component Isolate Switch
Malfunction Indication
Windows™ Digital Control System
Real-Time
Performance
Hampden's line of Computer Assisted Panel Instruction Modules have been
designed to provide realistic System Operation & Troubleshooting functions
to virtually Any Classroom!
Each module’s front panel is silkscreened with a complete
schematic & pictorial layout of all system operations and combined with
actual test-point pushbuttons, LEDs and meters.
All units are controlled via a PC computer (not supplied)
using supplied Hampden software and interface cards.
Each module’s front panel displays a complete schematic
and pictorial view of the system.
Realistic Problem
Solving in the Classroom
All Instruction Modules have the capability of inserting system specific
Mechanical & Electrical malfunctions -
singly or in multiples. This gives students the added experience of
resolving realistic problem situations which would otherwise be very difficult
for an instructor to create in a classroom.
MODEL H-DGCD-CSI Gas or H-DECD-CSI Electric Clothes Dryer Simulator
Additional Features:
Dampness Control Disconnect
Timer
Separate Meters for Voltage,
MODEL H-DAACS-CSI Automotive Air Conditioning Simulator

Additional Features:
Suction, Discharge, Pressure & Temperature Gauges
Built-In Voltage and Continuity Probes
Adjustable Ambient Temperature Control
Three-Speed Fan Control and LPCO Control
Adjustable RPM Control
MODEL H-DCWS-CSI Clothes Washer Simulator
Cycling Motor Disconnects
Active Circuit Breaker
Separate Meters for Voltage, Current,
Complete Action Thermostat
Ohmmeter/Line Voltage Interlock
Complete Voltage/Resistance Test Points
MODEL H-DACS-CSI Air Conditioner Simulator

Suction and Discharge Pressure Gauges
CHARGE (refrigerant) Control
Two Large Identified Air Flow Checks
Motor Disconnects
Active Circuit Breaker
Complete Action Thermostat
Separate Meters for Voltage,
MODEL H-DOHS-CSI Oil Heating System

Additional Features:
Draft Meter, Overfire/Stack/Chimney
Oil Tank Level Indicators
Spark Indicator
Burner Air Flow Control
Adjustable Draft Regulator
Boiler Temperature/Pressure
Smoke Test Meter
Two Zone Circulation Pumps
Flue CO2 Meter
Burner Suction/Discharge Meters
MODEL H-DRFS-CSI Refrigeration/Freezer Simulator

Additional Features:
Suction and Discharge Pressure Gauges
Refrigerator/Freezer Thermometers
Adjustable Temperature Control
Charge (Refrigerant)
Control Condenser/Evaporator Air Flow Indicators
Six Customer Control Switches
Separate Meters for Voltage,
MODEL H-DACH-CSI
Absorption Chiller/Heater Simulator
Additional Features:
Low Temperature Cut-out
High Pressure Relief
Chilled Water Flow Switch
Cooling Water Flow Switch
Monitoring of Burner and Generator
Temperature and Pressure Monitoring:
First-stage Generator
Second-stage Generator
Evaporator and Condenser
High and Lo Temperature Heat
Exchanger
Absorber
Microprocessor Based Control Panel
MODEL H-DHPS-CSI Heat Pump Simulator

Additional Features:
Gas Suction & Discharge Pressures
Two-step Indoor Thermostat
Outdoor Building Thermostat
Dynamic Temperature Variation/Adjustable Outdoor Temperature
Ohmmeter/Line Voltage Interlock
Outdoor Coil Thermostat
Supply Air Temperature Monitor
Light Identified Motor/Relay Action
Active Inside Temperature Indicator
Refrigerant (CHARGE) Control
Two Different Motor Types
High Pressure Cut-out Switch
Four Student Activated Visual Checks
MODEL H-DWTS-CSI
Wastewater Treatment Simulator.
Additional Features:
Incoming Flow
Influent pH
Bar Rack Screening
Primary Sludge Removal
Initial Dissolved Oxygen
Mid Dissolved Oxygen
Final Dissolved Oxygen
Flocculation
Return Activation Sludge (RAS)
Waste Activated Sludge (WAS)
BOD and TSS Levels
Disinfection (Cl) Injector
Residual Chlorine Removal
Effluent pH
MODEL H-DOHE-CSI Oil
Heating Electric Simulator
Additional Features:
Cad Cell Tester
Complete Primary Control Circuit
Spark Indicator
Water Temperature Gauge
Dynamic Temperature Variation
Ohmmeter/Line Voltage Interlock
Schematic and Pictorial Test Points
Malfunction Indication
Specifications Chart
Flame Indicator
Boiler Low Temperature Limit Switch
Light Identified Motor/Relay Action
Four Scale Multimeter
Two Water Circulation Pumps
Complete Four Relay Control Circuitry
Two Different Meter Types
Electrode Isolation
Two Zone Thermostats & Thermometers
MODEL H-DMCTT Motor Control Troubleshooting Trainer

Additional Features:
Three-Wire Control Circuit
Multiple Station Control Circuit
Sequence Control Circuit
Reverse Starter Control Circuit
Compelling Control Circuit
LEDs Represent Motor Coils and
Motors.
AC Voltmeter
Ohmmeter
Panel Power Supply
Eight Pushbuttons for Motor Control Functions.
Options For All
Trainers
MODEL H-CSI-CS
Pentium™ Desktop Computer System
MODEL H-CAI-PO
Printer